MS-700 drone-borne or walking detector
Applications
The Medusa Radiometrics MS-700 product line of radiation detection systems comprises a line of low-power, lightweight and robust gamma-ray sensors for walking or drone-borne applications. These systems are fully self-contained as they integrate data acquisition, processing and storage into a single embedded system. The MS-700 can also be used as a handheld system, operated from a smartphone or tablet PC using the Medusa Detector Operation System (mDOS).
Technology
The system comprises a 3x6 inch (700 ml) CsI-based scintillation detector connected to a tailor-made spectrum processing unit. This unit contains a 4096-channel MCA, an RTK-ready GPS, real-time data processing and embedded storage. The system works as a stand-alone unit, and the data can be viewed by connecting to the interface via WiFi or ethernet on a cabled connection.
The unit runs the Medusa Detector Operation System (mDOS) that provides access to the multiple functions of the device:
Set-up of the system;
Status view to inspect data and functioning of the system;
Single and continuous measurement modes;
View the data in real-time plotted on a map;
Download data for custom post-processing.
The data is stored in records containing energy-stabilized gamma-ray spectra, with count rate and activities of 40K, 238U, 232Th and 137Cs. Other radionuclides can be added on request. The data is geo-referenced using the built-in GPS.
System Operation
The system is designed for minimum operator interaction. It provides various views on the data streams while being acquired, allowing for online system checks. The system has embedded data storage with a standard capacity of 16GB, yielding space for over 700 hours of continuous data logging. The system can be user-configured to output gamma-ray spectra continuously, connecting the sensor to multiple data acquisition systems.
Specifications
Key Parameters
High sensivity
Lightweight and rugged carbon housing
CsI scintillator for enhanced stability
Full spectrum recording
Automatic gain stabilization
Online nuclide-specific count rates
On-board data logging
Set-up, control and viewing of data via built-in webserver running mDOS
Radiation Sensor
CsI crystal, other crystal types on request
Dedicated Spectrum Processing Unit comprising
4096 channel MCA,
Spectrum stabilization
Nuclide-specific data
System Data
Housing: Carbon fiber; end caps: Anodized aluminum
Connectors: one 8-pin LEMO Artic grip M-series
Environmental:
-40 0C to +85 0C;
IP68 protectedPower input 5-35V, (3W nominally, 6W max)
Data acquisition rate: up to 10Hz
Data storage capacity: 16GB internal
Wireless connection via WIFI and Bluetooth
Battery-powered
Connectivity: user-configurable output streams over IP or serial link
MS-700
Size: 100mm ⌀ x 300mm (L)
Weight: 4100 gram (NaI), 4700 g (CsI), 5100 g (CeBr)